Describe the operation of single phase half wave controlled rectifier with RL load.
Describe the operation of single phase half wave controlled rectifier with RL load.
Ans:
Circuit diagram:
Working:- During positive half cycle of input voltage, thyristor T is forward biased but it does
not conduct until gate signal is applied to it.
- When a gate signal is given to thyristor T at wt = α, it gets turned ON and begins to
conduct.
- When thyristor is ON the input voltage is applied to the load, but due to the inductor
present in the load, current through load builds up slowly.
- During negative half cycle of input voltage, thyristor T is reverse biased but current
through thyristor is not zero due to inductor.
- The current through inductor slowly decays to zero
- So here thyristor will conduct for some time during the negative half cycle and turns
OFF at wt = β.
- Now the load receives voltage during positive half cycle and for a small duration in
negative half cycle.
- The average value of voltage can be varied by varying firing angle α.